The dew point ventilation control is used for automatic cellar ventilation to reduce humidity.
The best time to ventilate is determined from the dew point, using two precision sensors measuring both the internal and external air temperature and humidity. The control unit then automatically switches on the SOLO+ fan.
Up to 10 SOLO+ fans can be connected to the dew-point control. Each SOLO+ ventilation system covers a cellar area of 30 m².
We supply the dew point control unit as standard with the app and wired sensors (Wi-Fi is required for the wireless sensors), and without a radio receiver (i.e. the power supply of the fans comes directly from the dew-point control unit).
If you connect several SOLO+ fans, you can set them to cross-ventilation mode directly on the dew-point control.
Optionally available:
The function of the dew point control is explained below. Temperature and humidity sensors measure the indoor and outdoor temperature and humidity. The control unit records and evaluates these readings. When you set up the control unit, you define the following parameters:
The control unit ventilates when it is drier outside than inside to dry the room. Otherwise, the message “It is not dry enough outside” appears. The absolute humidity is used for this, not the relative humidity. You can see the absolute humidity on the last line of the display. In addition, other conditions must be met for the ventilation to be switched on:

The indoor temperature must be within the set limits. The minimum and maximum temperatures you set are crucial for this. Otherwise, the message “Minimum temperature reached” or “Maximum temperature reached” appears. If the indoor temperature is outside these limits, the device can only ventilate if the outdoor temperature is such that ventilating brings the indoor temperature closer to the set limits (heating or cooling the room). Example 1: Indoor temperature: 18 °C, minimum temperature: 20 °C, maximum temperature: 27 °C. The indoor temperature is outside the limits. Ventilation can only take place when the outdoor temperature is greater than 18 °C so that the room can be heated and thus brought closer to 20 °C.
Example 2: Indoor temperature: 28 °C, minimum temperature: 20 °C, maximum temperature: 27 °C. The indoor temperature is outside the limits. Ventilation can only take place when the outdoor temperature is lower than 28 °C so that the room can be cooled and thus brought closer to 27 °C. The relative humidity inside must be greater than the set target humidity. Otherwise, the message “Target humidity reached” appears. In addition, the current time must be within the working time limits you have set. Otherwise, the message “Outside working hours” will appear. If the conditions are met, the device switches the ventilation on. This continues for as long as the conditions remain met, or until the set ventilation time has elapsed. Regardless of why the ventilation is switched off again, the message “Fan pause” always appears on the display. Only after the pause are all conditions checked again and ventilation can begin again. Example: absolute humidity inside: 12, absolute humidity outside: 10.8, difference: 1.0, ventilation: off.
Since the absolute humidity inside is greater than the absolute humidity outside plus the difference (12 > 11.8), the ventilation is now switched on (provided the other conditions are also met). It is only switched off at the end of the ventilation time or when the absolute humidity outside is at least as high as the absolute humidity inside
(difference for switching off is always 0). After the pause, the device is only switched on again when the difference of 1.0
is maintained. The cycle from this example then starts again.
A radio receiver, to which you can connect the fan, is available as an option.
It allows you to use nearby sockets with no need to run cables across different rooms.

The app allows you to analyse daily and monthly internal and external humidity and temperature values. It also provides real-time data on device operation thanks to an operating hours meter and event recorder.
The app runs on Android, Windows and iOS devices.

If required, the dew-point control can also communicate via Wi-Fi. It simply connects to your Wi-Fi network like a mobile phone, and it is ready for operation.
The humidity level in the basement (approx. 25 sqm) decreased by 15% (!!!!) rel. humidity within 2 days (continuous operation) and remains stable with +/- 1% (approx. 58%). I no longer need an electric dehumidifier ..... The system is quiet. The temperature also remains stable at 19.5-20.5 degrees. I can now use that part of the basement as an office.... You helped me a lot. Many thanks to you and your team...
Lutz T.
379,00 €
Prices incl. VAT plus Shipping
The Ambientika solo+, suitable for single-room solutions, operates autonomously without requiring manual control. This model can be connected to the dew-point control or radon measurement system. For living spaces and bedrooms, the other models with sensor technology are recommended, as they run more quietly thanks to their whisper-quiet night mode.
Tip: If the Solo+ units are coupled with the time delay module (accessory), the optimal effect of cross ventilation can be achieved.
579,00 €
Prices incl. VAT plus Shipping
With integrated sensor technology.
519,00 €
Prices incl. VAT plus Shipping
With integrated sensor technology.