Description
The negative-pressure monitor ensures safety when a fireplace and a ventilation system run at the same time: it monitors the air pressure and reliably prevents a dangerous negative pressure in the room.
- Protects room-air-dependent fireplaces (chimneys, tiled stoves) from dangerous negative pressure
- Automatically switches off the ventilation system as soon as a critical pressure difference is detected
- Prevents flue gases and carbon monoxide from entering the living space
- Simple electrical installation, compatible with all Ambientika models
- DIBt approval: Z-85.1-27
Description
A (room-air dependent) fireplace draws all or part of the required combustion air from the room in which it is installed or from other internal rooms, which might be dangerous if a ventilation system or a cooker hood is operated at the same time. By continuously drawing in air, these devices can create negative air pressure, which in turn reverses the draught in the flue. If the negative air pressure is strong enough, the toxic combustion gases are no longer vented through the chimney but may instead escape into the home. This can lead to serious illness or even fatal carbon monoxide poisoning. The risk can be reduced by making the fireplace independent of ambient air. However, this solution may not always be practical because of the structural restrictions on many fireplaces and tiled stoves. Fortunately, there is an easier option – our negative air pressure monitor, which disconnects the ventilation system in case of emergency.
The following conditions must be fulfilled for pressure-neutral operation:
- An even number of Ambientika devices on the same floor as the wood-burning stove
- Sufficient air transfer between the rooms: e.g. a 5 mm gap at the base of the door or an equivalent measure
- Correct installation and settings that ensure synchronous operation
If the master unit is disconnected from the power circuit by the pressure monitor in an emergency, the slave units will automatically stop operating
The pressure monitor can be installed in any room. The power supply to the ventilation units must be provided via the pressure monitor. One sensor hose must be led outdoors. The other sensor hose must be led into the room where the stove is located.
Pressure monitor dimensions
Width 16cm
Height 8cm
Depth 4cm
What does a negative pressure monitor do?
A negative pressure monitor is a device that monitors the pressure in a system and ensures that the pressure remains within a specified range. It is based on a simple principle: a system which is under pressure has air or gas flows which may fail under certain conditions. If this occurs, then the pressure in the system may rise or fall and may result in malfunctions or damage.
A negative pressure monitor consists of a sensor that measures the pressure in the system and a switch that analyses the information from the sensor and carries out appropriate actions. If the pressure in the system falls below a certain threshold, the switch is activated and a signal is sent to a control device which switches the system off or issues a warning message. This ensures that no damage to the system occurs and that efficient operation is maintained.
When is a negative pressure monitor essential?
A negative pressure monitor is particularly important under the following circumstances:
- In plants and systems which require a vacuum in order to function properly, such as vacuum tanks or vacuum pumps.
- In production processes in which a vacuum is essential, such as in the semiconductor industry or in the production of medical products.
- In areas in which hazardous or toxic vapours or gases may be released which could get into adjoining rooms if negative pressure occurs.
- In waste disposal systems or biogas plants in which a vacuum may occur owing to the decomposition of organic material.
- In patient rooms in hospitals in which negative pressure is required in order to prevent the spread of pathogens.
In general, a negative pressure monitor is always required if negative pressure is specified as a mandatory condition for a system or process and deviation from this may result in serious consequences.
Where is the negative pressure monitor installed?
The negative pressure monitor is generally installed near the exhaust air system or the ventilation system in order to measure the negative pressure in a room or a group of rooms. It can also be installed in rooms which potentially contain contaminated air, for example in medical facilities such as hospitals or laboratories. The exact place of installation depends on the specific application and requirements.
The device is housed in a plastic casing with external dimensions of 160 × 80 × 40 mm.
Compare our models
Ambientika solo+
379,00 €
Prices incl. VAT plus Shipping
The Ambientika solo+, suitable for single-room solutions, operates autonomously without requiring manual control. This model can be connected to the dew-point control or radon measurement system. For living spaces and bedrooms, the other models with sensor technology are recommended, as they run more quietly thanks to their whisper-quiet night mode.
Tip: If the Solo+ units are coupled with the time delay module (accessory), the optimal effect of cross ventilation can be achieved.
- Includes a set of G3 filters
- Infrared remote control with three speed levels included in the set
- Minimal noise emissions – high-tech fan positioned behind the heat exchanger
- Made with high-quality materials
- Automatic operation makes it ideal for rental properties
- Energy-efficient
- Thermal barrier in summer and winter – supply air close to room temperature
Ambientika advanced+
519,00 €
Prices incl. VAT plus Shipping
With integrated sensor technology.
- Automatic operation
- Unit supplied with remote control and wall mounting bracket
- Can be wired to up to 15 other units
- Minimal noise emissions – high-tech fan positioned behind the heat exchanger
- Free cooling by remote control – cool night air without heat recovery
- Thermal barrier in summer and winter – supply air close to room temperature
Ambientika wireless+
579,00 €
Prices incl. VAT plus Shipping
With integrated sensor technology.
- Automatic operation
- Unit supplied with remote control and wall mounting bracket
- Can be wirelessly connected to up to 15 other units
- Minimal noise emissions – high-tech fan positioned behind the heat exchanger
- Safe and reliable radio frequency (with built-in transmitter/receiver)
- Free cooling by remote control – cool night air without heat recovery
- Thermal barrier in summer and winter – supply air close to room temperature